Evaluation of multivariate calibration models transferred between spectroscopic instruments: applied to near infrared measurements of flour samples
Research output: Contribution to journal › Journal article › Research › peer-review
Standard
Evaluation of multivariate calibration models transferred between spectroscopic instruments : applied to near infrared measurements of flour samples. / Eskildsen, Carl Emil Aae; Hansen, Per W.; Skov, Thomas; Marini, Federico; Nørgaard, Lars.
In: Journal of Near Infrared Spectroscopy, Vol. 24, No. 2, 2016, p. 151-156.Research output: Contribution to journal › Journal article › Research › peer-review
Harvard
APA
Vancouver
Author
Bibtex
}
RIS
TY - JOUR
T1 - Evaluation of multivariate calibration models transferred between spectroscopic instruments
T2 - applied to near infrared measurements of flour samples
AU - Eskildsen, Carl Emil Aae
AU - Hansen, Per W.
AU - Skov, Thomas
AU - Marini, Federico
AU - Nørgaard, Lars
PY - 2016
Y1 - 2016
N2 - In a setting where multiple spectroscopic instruments are used for the same measurements it may be convenient to develop the calibration model on a single instrument and then transfer this model to the other instruments. In the ideal scenario, all instruments provide the same predictions for the same samples using the transferred model. However, sometimes the success of a model transfer is evaluated by comparing the transferred model predictions with the reference values. This is not optimal, as uncertainties in the reference method will impact the evaluation. This paper proposes a new method for calibration model transfer evaluation. The new method is based on comparing predictions from different instruments, rather than comparing predictions and reference values. A total of 75 flour samples were available for the study. All samples were measured on ten near infrared (NIR) instruments from two instrumental platforms, five NIR instruments from each platform. Protein content was quantified for all 75 samples and used as the reference variable during modelling by partial least squares regression. By adding artificial noise to first the spectroscopic measurements and then the reference values, this paper highlights the problems of including reference values in the evaluation of a model transfer, as uncertainties in the reference method impact the evaluation. At the same time, this paper highlights the power of the proposed model transfer evaluation, which is based on comparing predictions obtained from the different instruments. In this way, the impact of uncertainties originating from the reference method is minimised.
AB - In a setting where multiple spectroscopic instruments are used for the same measurements it may be convenient to develop the calibration model on a single instrument and then transfer this model to the other instruments. In the ideal scenario, all instruments provide the same predictions for the same samples using the transferred model. However, sometimes the success of a model transfer is evaluated by comparing the transferred model predictions with the reference values. This is not optimal, as uncertainties in the reference method will impact the evaluation. This paper proposes a new method for calibration model transfer evaluation. The new method is based on comparing predictions from different instruments, rather than comparing predictions and reference values. A total of 75 flour samples were available for the study. All samples were measured on ten near infrared (NIR) instruments from two instrumental platforms, five NIR instruments from each platform. Protein content was quantified for all 75 samples and used as the reference variable during modelling by partial least squares regression. By adding artificial noise to first the spectroscopic measurements and then the reference values, this paper highlights the problems of including reference values in the evaluation of a model transfer, as uncertainties in the reference method impact the evaluation. At the same time, this paper highlights the power of the proposed model transfer evaluation, which is based on comparing predictions obtained from the different instruments. In this way, the impact of uncertainties originating from the reference method is minimised.
KW - Calibration
KW - Evaluation
KW - Model transfer
KW - Near infrared spectroscopy
U2 - 10.1255/jnirs.1210
DO - 10.1255/jnirs.1210
M3 - Journal article
AN - SCOPUS:84969895651
VL - 24
SP - 151
EP - 156
JO - Journal of Near Infrared Spectroscopy
JF - Journal of Near Infrared Spectroscopy
SN - 0967-0335
IS - 2
ER -